<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Qubit Systems Inc. &#187; Cardiopulmonary Sensing</title>
	<atom:link href="http://qubitsystems.com/category/product_list/cardiopulmonary-sensing/feed/" rel="self" type="application/rss+xml" />
	<link>http://qubitsystems.com</link>
	<description>Instrumentation for the Biological Sciences</description>
	<lastBuildDate>Tue, 08 May 2012 18:38:43 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1.1</generator>
		<item>
		<title>Q-CPX System</title>
		<link>http://qubitsystems.com/human/q-cpx-system/</link>
		<comments>http://qubitsystems.com/human/q-cpx-system/#comments</comments>
		<pubDate>Thu, 14 Apr 2011 17:54:41 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Cardiopulmonary]]></category>
		<category><![CDATA[Cardiopulmonary Sensing]]></category>
		<category><![CDATA[Featured Human Products]]></category>
		<category><![CDATA[Human]]></category>
		<category><![CDATA[Human Landing]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[CPX]]></category>
		<category><![CDATA[exercise testing]]></category>
		<category><![CDATA[metabolic analyzer]]></category>

		<guid isPermaLink="false">http://qubitsystems.com/?p=4265</guid>
		<description><![CDATA[Q-CPX System is a new Cardiopulmonary Exercise Testing System, complete with the CPX Metabolic analyzer including heart rate monitor pneumotach spirometer.]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-system.jpg"><img class="size-medium wp-image-4269 alignleft" title="CPX system" src="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-system-231x300.jpg" alt="" width="146" height="201" /></a></p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="319" valign="top"><strong>INCLUDED</strong></td>
<td width="319" valign="top"><strong>OPTIONS</strong></td>
</tr>
<tr>
<td width="319" valign="top"><strong>Rapid Response O2 Analyzer</strong></td>
<td width="319" valign="top"><strong>12 Lead EKG</strong></td>
</tr>
<tr>
<td width="319" valign="top"><strong>Rapid Response CO2 Analyzer</strong></td>
<td width="319" valign="top"><strong>Bicycle Ergometer</strong></td>
</tr>
<tr>
<td width="319" valign="top"><strong>Heart Rate Monitor</strong></td>
<td width="319" valign="top"><strong>Blood Pressure Measurements</strong></td>
</tr>
<tr>
<td width="319" valign="top"><strong>Pneumotach Spirometer</strong></td>
<td width="319" valign="top"><strong>SpO2 Monitor</strong></td>
</tr>
<tr>
<td width="319" valign="top"><strong>Calibration Syringe</strong></td>
<td width="319" valign="top"><strong>Metabolic Cart</strong></td>
</tr>
<tr>
<td width="319" valign="top"><strong>PC with ComPAS Software</strong></td>
<td width="319" valign="top"><strong>Pulmonary Function Accessories</strong></td>
</tr>
</tbody>
</table>
<p>The <strong>Q-CPX </strong>is a new Cardiopulmonary Exercise Testing System, complete with the CPX Metabolic Analyzer for breath by breath CO2 and O2 exchange measurements.  Included is a pneumotach spirometer for breath flow and volume measurements, and a heart rate monitor.   Options include a sturdy cart, bicycle ergometer, blood pressure monitor, blood saturation oximeter and a12-lead EKG.  The software monitors outputs from all sensors as well as controlling the ergometer with standard and customizable test procedures. </p>
<p>Precise breath by breath analysis is conducted using a combined rapid response NDIR CO2 analyzer and laser diode O2 Analyzer.   Comfortable face masks are provided that do not impede natural breathing, and which are inexpensive enough for single subject use.  The system includes a PC running the renowned <strong>ComPAS Software </strong>suite<strong> </strong>for automated cardiovascular fitness measurements.   </p>
<p>Calibration of the gas analyzers and the pneumotach spirometer is fully automated, set up is minimal and accuracy is assured.   The data display can be customized for specific applications, or one of several default configurations may be used.   Both raw and calculated parameters such as VO2, VCO2, RER, RR, Vt, VE, ETO2, ETCO2, HR etc are displayed and can be manipulated both in graphical and tabular format.  In addition to breath analysis, pulmonary tests can be performed, displayed and saved during an exercise test.</p>
<p><a href="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-RER-data.jpg"><img class="size-medium wp-image-4437 alignleft" title="CPX-RER data" src="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-RER-data-300x247.jpg" alt="" width="240" height="198" /></a></p>
<p><strong> </strong> </p>
<p><strong> </strong> </p>
<p><strong> </strong> </p>
<p><strong> </strong></p>
<p><em>RER data screen</em></p>
<p><strong> </strong> </p>
<p><strong> </strong></p>
<p><strong>ComPAS Certified Software </strong>has been developed over a period of 30 years, and is used extensively in hospitals throughout the USA.   It provides an extensive data base for patient records, and permits patient tracking, record keeping and reporting.  During an exercise test, the software guides the user through each stage of the procedure with a simple graphical user interface, ensuring that all procedures, and any necessary calibrations, are followed exactly.  An extensive help menu is built directly into the software. </p>
<p>As well as providing best in class data acquisition for cardiopulmonary exercise testing, <strong>ComPAS</strong> includes comprehensive protocols for pulmonary function testing.</p>
<p><span style="line-height: 115%; font-family: &quot;Times New Roman&quot;,&quot;serif&quot;; font-size: 12pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">.</span></p>
<p><a href="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-Patient-Entry.jpg"><img class="alignleft size-medium wp-image-4436" title="CPX- Patient Entry" src="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-Patient-Entry-300x210.jpg" alt="" width="240" height="168" /></a></p>
<p><a href="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-.jpg"></a> </p>
<p> <em>Patient records screen</em></p>
<p><strong> </strong> </p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<p><strong><a href="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-1.jpg"><img class="alignleft size-medium wp-image-4444" title="CPX" src="http://qubitsystems.com/wp-content/uploads/2011/04/CPX-1-300x166.jpg" alt="" width="300" height="166" /></a> </strong></p>
<p><strong> </strong></p>
<p><em>Metabolic Rate Analyzer</em></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<p><strong>Specifications of Metabolic Rate Analyzer:</strong></p>
<p><span style="text-decoration: underline;">CO2 Sensor</span></p>
<ul>
<li>Operating Principle &#8211; Infrared Spectroscopy</li>
<li>CO2 Range &#8211; 0% to 13%</li>
<li>Operating Temperature &#8211; 5°C to 55°C</li>
<li>Power Consumption &#8211; 335 mW</li>
<li>Response Time &#8211;   Detector &#8211; 28 ms (typical), System &#8211; 100 ms (typical)</li>
<li>Breath Rate- &gt;60 bpm</li>
</ul>
<p><span style="text-decoration: underline;">O2 Sensor</span></p>
<ul>
<li>Operating Principle- Laser Diode - Optical Absorption</li>
<li>Range &#8211; 5% to 100%</li>
<li>Resolution &#8211; 0.01 Vol.% O2</li>
<li>Linearity &#8211; 0.2 Vol.%</li>
<li>Response time (T90) &#8211; 130 ms @ 200 mL/min flow</li>
<li>Operating Temperature &#8211; 0°C to 50°C</li>
<li>Operating Relative Humidity  &#8211; 5 to 95%</li>
<li>Operating Pressure &#8211; 25 to 115 kPa</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/human/q-cpx-system/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S185 Hand-grip Heart Rate Monitor</title>
		<link>http://qubitsystems.com/human/s185-hand-grip-heart-rate-monitor/</link>
		<comments>http://qubitsystems.com/human/s185-hand-grip-heart-rate-monitor/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 16:02:48 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Cardiopulmonary]]></category>
		<category><![CDATA[Cardiopulmonary Sensing]]></category>
		<category><![CDATA[Human]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Ideal for determining a person’s heart rate while mobile or stationary]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S185-hand-grip-Heart-rate-monitor.jpg"><img class="alignnone size-medium wp-image-3248" title="S185 hand grip Heart rate monitor" src="http://qubitsystems.com/wp-content/uploads/2010/06/S185-hand-grip-Heart-rate-monitor-300x137.jpg" alt="" width="300" height="137" /></a></p>
<p>Qubit&#8217;s  <strong>S185 Hand-Grip Heart Rate Monitor</strong> is ideal for determining a person’s heart rate while mobile or stationary. With this sensor, heart rate can be monitored before, during, as well as after exercise. The sensor consists of wireless hand grips and a receiver module that plugs into the <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c410-labpro-data-acquisition-interface/" target="_blank"><span style="text-decoration: underline;">C410 LabPro Interface</span></a>. The hand grips sense the electrical signals generated by the heart, much like an ECG. For each pulse detected, a signal is transmitted to the receiver module, and the individual’s pulse rate is calculated.  We recommend using this monitor with <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank"><span style="text-decoration: underline;">C901 LoggerPro data acquisition software</span></a>.</p>
<p><strong>All human electrophysiology and human respiratory monitoring products produced by Qubit Systems Inc. are not appropriate for medical or clinical applications</strong></p>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/human/s185-hand-grip-heart-rate-monitor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S184 Spirometer</title>
		<link>http://qubitsystems.com/human/s184-spirometer/</link>
		<comments>http://qubitsystems.com/human/s184-spirometer/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 15:40:04 +0000</pubDate>
		<dc:creator>paul</dc:creator>
				<category><![CDATA[Cardiopulmonary]]></category>
		<category><![CDATA[Cardiopulmonary Sensing]]></category>
		<category><![CDATA[Human]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Used to perform a variety of tests related to air flow and lung volume]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S184-spirometer.jpg"><img class="alignnone size-full wp-image-3140" title="S184 spirometer" src="http://qubitsystems.com/wp-content/uploads/2010/06/S184-spirometer.jpg" alt="" width="435" height="200" /></a></p>
<p>Qubit&#8217;s <strong>S184 Spirometer</strong> can be used to perform a variety of tests related to air flow and lung volume. The Spirometer is designed to make human respiratory measurements at rest and during moderate activity.</p>
<p><strong>All human electrophysiology and human respiratory monitoring products produced by Qubit Systems Inc. are not appropriate for medical or clinical applications</strong></p>
<p>The sensor of the <strong>S184 Spirometer</strong> includes a removable flow head (22 mm ID / 30 mm OD) for easy cleaning and sterilization, and a differential pressure transducer. The Spirometer package includes 1 sensor handle, 1 flow head, 5 disposable mouthpieces, 1 disposable bacterial filter, and 1 nose clip. The S184 Spirometer is included in the <span style="text-decoration: underline;"><a href="http://qubitsystems.com/human/q-box-hr1lp-human-respirometry-package/" target="_blank">Q-Box HR1LP Human Respirometry Package</a>.</span></p>
<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S184-spirometer-items.jpg"><img class="alignnone size-full wp-image-3141" title="S184 spirometer items" src="http://qubitsystems.com/wp-content/uploads/2010/06/S184-spirometer-items.jpg" alt="" width="250" height="277" /></a></p>
<p><strong>Available Accessories</strong> :</p>
<ul>
<li>Disposable Mouthpieces for S184 Spirometer (30/pkg) &#8211; A151</li>
</ul>
<ul>
<li>Disposable Bacterial Filter for S184 Spirometer (10/pkg) &#8211; A152</li>
</ul>
<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S184spirometer-data.jpg"><img class="alignnone size-full wp-image-3142" title="S184spirometer data" src="http://qubitsystems.com/wp-content/uploads/2010/06/S184spirometer-data.jpg" alt="" width="263" height="250" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/human/s184-spirometer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S182 Wireless Exercise Heart Rate Monitor</title>
		<link>http://qubitsystems.com/human/s182-wireless-exercise-heart-rate-monitor/</link>
		<comments>http://qubitsystems.com/human/s182-wireless-exercise-heart-rate-monitor/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 15:13:22 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Cardiopulmonary]]></category>
		<category><![CDATA[Cardiopulmonary Sensing]]></category>
		<category><![CDATA[Human]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Ideal for determining the heart rate of individuals]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S182-wireless-exercise-Heart-rate-monitor.jpg"><img class="alignnone size-full wp-image-3133" title="S182 wireless exercise Heart rate monitor" src="http://qubitsystems.com/wp-content/uploads/2010/06/S182-wireless-exercise-Heart-rate-monitor.jpg" alt="" width="450" height="207" /></a></p>
<p>The <strong>S182 Wireless Exercise Heart Rate Monitor</strong> is ideal for determining the heart rate of individuals. Using this sensor, a subject&#8217;s heart rate can be monitored before, during and after exercise.</p>
<p><strong>All human electrophysiology and human respiratory monitoring products produced by Qubit Systems Inc. are not appropriate for medical or clinical applications</strong></p>
<p>The <strong>S182 Exercise Heart Rate Monitor</strong> consists of a wireless transmitter belt and a receiver module designed to plug into a <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c410-labpro-data-acquisition-interface/" target="_blank"><span style="text-decoration: underline;">C410 LabPro Interface</span></a>. The transmitter belt senses the electrical signals generated by the heart, much like an EKG. For each heartbeat detected, a signal is transmitted to the receiver module, and a heart rate is determined. The voltage signal is transmitted to the computer via the interface and may be displayed as Beats per Minute (BPM) by <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank"><span style="text-decoration: underline;">C901 Logger Pro software</span></a>.  The Exercise Heart Rate Monitor is part of the <span style="text-decoration: underline;"><a href="http://qubitsystems.com/human/q-box-hr1lp-human-respirometry-package/" target="_blank">Q-Box HR1LP Human Respirometry Package</a></span> and <span style="text-decoration: underline;"><a href="http://qubitsystems.com/human/bbb1lp-breath-by-breath-package-o2-co2/" target="_blank">BBB1LP Breath by Breath Package (O2+CO2)</a>.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/human/s182-wireless-exercise-heart-rate-monitor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>