<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Qubit Systems Inc. &#187; Spectrometers</title>
	<atom:link href="http://qubitsystems.com/category/product_list/spectrometers/feed/" rel="self" type="application/rss+xml" />
	<link>http://qubitsystems.com</link>
	<description>Instrumentation for the Biological Sciences</description>
	<lastBuildDate>Tue, 08 May 2012 18:38:43 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1.1</generator>
		<item>
		<title>Z850 SpectraPen</title>
		<link>http://qubitsystems.com/environmental/z850-spectrapen/</link>
		<comments>http://qubitsystems.com/environmental/z850-spectrapen/#comments</comments>
		<pubDate>Thu, 17 Jun 2010 17:28:06 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Environment Landing]]></category>
		<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Light]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Spectrometers]]></category>
		<category><![CDATA[light meter]]></category>
		<category><![CDATA[light spectrum]]></category>
		<category><![CDATA[spectrometer]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[A handheld spectrometer pre-configured for two basic applications: spectrum measurements at UV/VIS 340 to 780 nm or NIR 640 to 1050 nm.]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/Z850-spectrapen-with-pointer.jpg"><img class="aligncenter size-full wp-image-2307" title="Z850 spectrapen with pointer" src="/wp-content/uploads/2010/06/Z850-spectrapen-with-pointer.jpg" alt="" width="308" height="197" /></a></p>
<p><strong>SpectraPen Z850</strong> is a handheld spectrometer. The SpectraPen is powered by Li-ion rechargeable battery and does not require any PC or other bulky accessories.  Light wavelength and intensity readings of any light source are instantly displayed as spectral traces on the SpectraPen touch screen display.  Optional  fiber optic cable is also available.</p>
<p>The SpectraPen is pre-configured for one of the two applications: spectrum measurements at <strong>UV/VIS 340 to 780 nm</strong> or <strong>NIR 640 to 1050 nm</strong>.</p>
<p><strong>Features:</strong></p>
<ul>
<li>Handheld and lightweight</li>
<li>Durable and low-cost</li>
<li>Wide spectral response range: UV/Vis: 340 – 780 nm<strong> or </strong>NIR: 640 – 1050 nm</li>
<li>No PC needed for operation</li>
<li>Intuitive touch-screen use</li>
<li>Flexibility in measurement setups</li>
<li>Battery-powered</li>
<li>USB connectivity for charging and data downloading</li>
</ul>
<p><strong>Applications:</strong></p>
<ul>
<li>Visible light source testing</li>
<li>Color measurement</li>
<li>Chemical measurement</li>
</ul>
<p><strong>Software:</strong></p>
<ul>
<li>Different operation modes: scope, absorbance, transmittance</li>
<li>Different tools: zoom, marker, auto scale, curve smoothing</li>
<li>Automated setting of the integration time</li>
<li>Data browsing</li>
<li>Data averaging</li>
</ul>
<p><strong>PC Connectivity:</strong></p>
<ul>
<li>Spectrum data collection</li>
<li>Export to Excel</li>
<li>Online control</li>
<li>Firmware update</li>
</ul>
<p><a href="/wp-content/uploads/2010/06/Z850-spectrapen-data1.jpg"><img class="aligncenter size-full wp-image-2306" title="Z850 spectrapen data" src="/wp-content/uploads/2010/06/Z850-spectrapen-data1.jpg" alt="" width="264" height="341" /></a></p>
<p><strong>Technical Specification:</strong></p>
<ul>
<li>Optical entrance:  SMA 905 to 0.22 numerical aperture single strand optical fiber</li>
<li>Spectral response range: 340nm &#8211; 780nm <strong>or</strong> 640nm &#8211; 1050nm</li>
<li>Spectral response half width *: 9 or 8</li>
<li>Spectral stray light *:  -30 dB</li>
<li>Wavelength reproducibility: +/- 0.5 nm</li>
<li>Integration time: 5 ms – 10 s</li>
<li>Number of pixel: 256</li>
<li>Dimension of pixel: 0.5 x 15.8 mm</li>
<li>Touch screen: 240 x 320 pixel; 65535 colors</li>
<li>Memory capacity: 32 MB (up to 8000 measurements)</li>
<li>System data: 16 bit AD conversion</li>
<li>Dynamic range: High gain- 1:4300; low gain- 1:13000</li>
<li>Communication: USB</li>
<li>Dimensions: 15 x 7.5 x 4 cm</li>
<li>Weight: 300 g</li>
<li>Case: Splash-proof</li>
<li>Battery: Li-ion; rechargeable via USB port of a PC</li>
<li>Battery life: 48 hours (continuous operation)</li>
<li>Operating temperature: 0 to +50 ºC</li>
<li>Storage temperature: -20 to +70 ºC</li>
</ul>
<p>** When monochromatic light of Λ = 550 nm or Λ = 850 nm is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured at a wavelength 40 nm longer or shorter than the input wavelength.</p>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/environmental/z850-spectrapen/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Z800 Spectrometer</title>
		<link>http://qubitsystems.com/environmental/z800-spectrometer/</link>
		<comments>http://qubitsystems.com/environmental/z800-spectrometer/#comments</comments>
		<pubDate>Fri, 09 Apr 2010 10:29:18 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Light]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Spectrometers]]></category>
		<category><![CDATA[light spectrum]]></category>
		<category><![CDATA[spectrometer]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[High-resolution, fiber optic spectroscopy in the UV/VIS to NIR range. ]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/04/Z800-spectrometer.jpg"><img class="alignnone size-medium wp-image-3218" title="Z800 spectrometer" src="http://qubitsystems.com/wp-content/uploads/2010/04/Z800-spectrometer-300x146.jpg" alt="" width="300" height="146" /></a></p>
<p>The new <strong>Z800 Spectrometer</strong> was developed for high-resolution, fiber optic spectroscopy applications in the UV/VIS to NIR range. It can be used as a stand-alone instrument or as a substantial enhancement of other instruments to analyze spectral composition of irradiance. Ultra-high sensitivity of the instrument allows measuring fluorescence emission spectra of individual cells when combined with <a href="/algae-and-bacteria/photosynthesis-respiration-algae-bacteria/z500-micro-fluorcam/" target="_blank"><span style="text-decoration: underline;"><strong>Z500 Micro FluorCam</strong></span></a>. The spectra can be measured in the range from UV (200 nm) to NIR (980 nm) with FWHM bandwidth of 3.5 nm. Fast recording can capture as many as 100 spectra per second with data resolution of 16 bits.</p>
<p><strong>Key features</strong></p>
<ul>
<li>Ultra-high sensitivity.</li>
<li>Suitable for microspectrophotometry.</li>
<li>FWHM bandwidth of 3.5 nm.</li>
<li>Small-footprint,</li>
<li>modular, robust, and thermally stable.</li>
<li>Very low heat generation.</li>
<li>10 µs &#8211; 10 ms duration of flashes.</li>
<li>Variable exposure time, from 1 millisecond to minutes.</li>
<li>Kinetic spectra (max. 100 per second).</li>
</ul>
<p><strong>Specifications:</strong></p>
<ul>
<li><strong>Optical Entrance:</strong> diameter 0.5 NA = 0.22 mounted in SMA-coupling, dismountable</li>
<li><strong>Entrance slit:</strong> 70 µm x 1400 µm (optical entrance)</li>
<li><strong>Grating</strong>: Flat-field correction</li>
<li><strong>Spectral range</strong>: 200 nm &#8211; 980 nm</li>
<li><strong>Wavelength accuracy absolute:</strong> &lt; 0.5 nm</li>
<li><strong>Reproducibility:</strong> &lt; 0.1 nm</li>
<li><strong>Temperature</strong> <strong>- induced drift </strong>&lt;0.01 nm/K</li>
<li><strong>Spectral distance of pixel:</strong> Δλ pixel ~ 0.8 nm</li>
<li><strong>(FWHM: Full width half maximum)</strong>: Δλ &lt; 3 &#8230;4 nm (UV-NIR Version)</li>
<li><strong>Straylight: </strong>0.1 % measured at 340 nm with deuterium lamp (transmission of NaNO2 solution, 50 g/l, 1 cm)</li>
<li><strong>CCD Array:</strong> Thermoelectrically cooled Hamamatsu S 7031</li>
<li><strong>Number of pixels:</strong> 1044 x 64</li>
<li><strong>Dimensions of pixels:</strong> 24 x 24 mm2</li>
<li><strong>System data</strong>: 16 Bit AD conversion</li>
<li><strong>Noise</strong>: 2&#8230;4 count standard deviation</li>
</ul>