<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Qubit Systems Inc. &#187; Respirometry Chambers</title>
	<atom:link href="http://qubitsystems.com/category/product_list/aquatic-respirometry/respirometry-chambers/feed/" rel="self" type="application/rss+xml" />
	<link>http://qubitsystems.com</link>
	<description>Instrumentation for the Biological Sciences</description>
	<lastBuildDate>Tue, 08 May 2012 18:38:43 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1.1</generator>
		<item>
		<title>D602 Glass Micro-Respiration Chambers</title>
		<link>http://qubitsystems.com/aquatic/d602-glass-micro-respiration-chambers/</link>
		<comments>http://qubitsystems.com/aquatic/d602-glass-micro-respiration-chambers/#comments</comments>
		<pubDate>Fri, 20 Aug 2010 17:07:01 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Landing]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[A handmade micro-respiration chamber consisting of two parts: a custom-sized glass chamber and a 3-port glass stopper made for intermittent flow respirometry.]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/08/d602.png"><img class="aligncenter size-full wp-image-2538" title="d602" src="/wp-content/uploads/2010/08/d602.png" alt="" width="550" height="350" /></a>The <strong>D602</strong> is a handmade micro-respiration chamber consisting of two parts:</p>
<ul>
<li>a custom-sized glass chamber of variable volume (500 &#8211; 5000 µl), inner diameter is 11.2 mm</li>
<li>a 3-port glass stopper made for intermittent flow respirometry using fiber-optic needle-type sensors (O2 or pH) or other micro sensors.</li>
</ul>
<p><strong>Included:</strong></p>
<ul>
<li>One custom-sized glass chamber</li>
<li>One 3-port glass stopper</li>
<li>One glass spacer</li>
<li>One glass coated magnetic stir bar</li>
<li>Stainless steel net for separation of magnet and fragile samples, 10 cm<sup>2</sup></li>
</ul>
<p><strong>Features:</strong></p>
<ul>
<li>Volumes in the range of 0.5 &#8211; 5 mL are available to fit different respiration or photosynthetic rates</li>
<li>Designed for intermittent flow respirometry for long-term experiments with high temporal resolution and sensitivity</li>
<li>No materials acting as oxygen sources or sinks</li>
<li>Chamber and stopper made in borosilicate glass to give a tight seal and prevent diffusion of oxygen between the chamber and surroundings</li>
<li>Designed for use with oxygen micro sensors featuring no O2 consumption, low response time, no stir effect, no cross-sensitivity, no electrical interference, sterilizable (H2O2, EtOH) etc.</li>
</ul>
<p>NB: every chamber is handmade from borosilicate glass and therefore, their exact volumes have to be determined individually!</p>
<p><strong>Measuring Principle:</strong></p>
<p>One port is for the micro sensor and is made as an open capillary tube (0.75 ×14 mm) so tiny that it effectively prevents diffusion of air if filled with water or oil. The other two ports are for flushing the chamber intermittently with a peristaltic pump. Both of these are fitted with pieces of steel needle for tygon tubes.</p>
<p>Fragile samples are separated from the glass-coated magnetic stir bar, by placing a piece of stainless steel net (mesh size 250 µm) on top of a glass spacer O-ring.</p>
<p><strong>Applications:</strong></p>
<ul>
<li>Oxygen consumption of individual eggs, embryos and larvae (invertebrates, fish)</li>
<li>Net oxygen evolution and respiration rates of phytoplankton cultures of low density</li>
<li>Other applications with very low oxygen fluxes</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d602-glass-micro-respiration-chambers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D012 Static Respirometry Chamber (190mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d012-static-respirometry-chamber-190mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d012-static-respirometry-chamber-190mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 15:20:52 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish) (190mm ID) ]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/d012.png"><img class="aligncenter size-full wp-image-2521" title="d012" src="/wp-content/uploads/2010/06/d012.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often, fish). The chambers have 2 ports located on each end of the to allow water in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber.</p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p><span>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</span></p>
<ul>
<li><span>Free choice of chamber length, and 8 different inner diameters</span></li>
<li><span>Chambers made for use in full strength sea water</span></li>
<li><span>Easy tool-free handling and cleaning</span></li>
<li><span>Smaller chambers made of glass to avoid O<span>2</span> storage/release</span></li>
<li><span>Built-in baffles for even distribution of flow</span></li>
</ul>
<ul>
<li>For flushing and recirculating the water in the chamber pumps are needed. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>To connect the pumps with the respirometer tubing is needed.</li>
<li>Place the oxygen probe in one of our inline flow-through chambers (D025, D026, D027).</li>
<li>Replacement glass tubes are available, please contact us for details.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d012-static-respirometry-chamber-190mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D011 Static Respirometry Chamber (80mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d011-static-respirometry-chamber-80mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d011-static-respirometry-chamber-80mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 15:17:44 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish) (80mm ID) 

]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/D011.png"><img class="aligncenter size-full wp-image-2518" title="D011" src="/wp-content/uploads/2010/06/D011.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often, fish). The chambers have 2 ports located on each end of the to allow water in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber.</p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p><span>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</span></p>
<ul>
<li><span>Free choice of chamber length, and 8 different inner diameters</span></li>
<li><span>Chambers made for use in full strength sea water</span></li>
<li><span>Easy tool-free handling and cleaning</span></li>
<li><span>Smaller chambers made of glass to avoid O<span>2</span> storage/release</span></li>
<li><span>Built-in baffles for even distribution of flow</span></li>
</ul>
<ul>
<li>For flushing and recirculating the water in the chamber pumps are needed. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>To connect the pumps with the respirometer tubing is needed.</li>
<li>Place the oxygen probe in one of our inline flow-through chambers (D025, D026, D027).</li>
<li>Replacement glass tubes are available, please contact us for details.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d011-static-respirometry-chamber-80mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D010 Static Respirometry Chamber (140mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d010-static-respirometry-chamber-140mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d010-static-respirometry-chamber-140mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 15:16:00 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish) (140mm ID) 

]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/D010.png"><img class="aligncenter size-full wp-image-2516" title="D010" src="/wp-content/uploads/2010/06/D010.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often, fish). The chambers have 2 ports located on each end of the to allow water in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber.</p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p><span>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</span></p>
<ul>
<li><span>Free choice of chamber length, and 8 different inner diameters</span></li>
<li><span>Chambers made for use in full strength sea water</span></li>
<li><span>Easy tool-free handling and cleaning</span></li>
<li><span>Smaller chambers made of glass to avoid O<span>2</span> storage/release</span></li>
<li><span>Built-in baffles for even distribution of flow</span></li>
</ul>
<ul>
<li>For flushing and recirculating the water in the chamber pumps are needed. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>To connect the pumps with the respirometer tubing is needed.</li>
<li>Place the oxygen probe in one of our inline flow-through chambers (D025, D026, D027).</li>
<li>Replacement glass tubes are available, please contact us for details.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d010-static-respirometry-chamber-140mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D009 Static Respirometry Chamber (72mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d009-static-respirometry-chamber-72mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d009-static-respirometry-chamber-72mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 14:55:01 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish) (72mm ID) 
]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/D009.png"><img class="aligncenter size-full wp-image-2514" title="D009" src="/wp-content/uploads/2010/06/D009.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often, fish). The chambers have 2 ports located on each end of the to allow water in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber.</p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p><span>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</span></p>
<ul>
<li><span>Free choice of chamber length, and 8 different inner diameters</span></li>
<li><span>Chambers made for use in full strength sea water</span></li>
<li><span>Easy tool-free handling and cleaning</span></li>
<li><span>Smaller chambers made of glass to avoid O<span>2</span> storage/release</span></li>
<li><span>Built-in baffles for even distribution of flow</span></li>
</ul>
<ul>
<li>For flushing and recirculating the water in the chamber pumps are needed. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>To connect the pumps with the respirometer tubing is needed.</li>
<li>Place the oxygen probe in one of our inline flow-through chambers (D025, D026, D027).</li>
<li>Replacement glass tubes are available, please contact us for details.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d009-static-respirometry-chamber-72mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D008 Static Respirometry Chamber (45mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d008-static-respirometry-chamber-45mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d008-static-respirometry-chamber-45mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 14:52:56 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish) (45mm ID) 
]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/D008.png"><img class="aligncenter size-full wp-image-2512" title="D008" src="/wp-content/uploads/2010/06/D008.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often, fish). The chambers have 2 ports located on each end of the to allow water in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber.</p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</p>
<ul>
<li>Free choice of chamber length, and 8 different inner diameters</li>
<li>Chambers made for use in full strength sea water</li>
<li>Easy tool-free <span>handling</span> and cleaning</li>
<li>Smaller chambers made of glass to avoid O<span>2</span> storage/release</li>
<li>Built-in baffles for even distribution of flow</li>
</ul>
<ul>
<li>For flushing and recirculating the water in the chamber pumps are needed. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>To connect the pumps with the respirometer tubing is needed.</li>
<li>Place the oxygen probe in one of our inline flow-through chambers (D025, D026, D027).</li>
<li>Replacement glass tubes are available, please contact us for details.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d008-static-respirometry-chamber-45mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D007 Static Respirometry Chamber (33mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d007-static-respirometry-chamber-33mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d007-static-respirometry-chamber-33mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 14:49:21 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish) (33mm ID).

]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/D0071.png"><img class="aligncenter size-full wp-image-2510" title="D007" src="/wp-content/uploads/2010/06/D0071.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish). The chambers have 2 ports located on each end to allow water flow in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber.</p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</p>
<ul>
<li>Free choice of chamber length, and 8 different inner diameters</li>
<li>Chambers made for use in full strength sea water</li>
<li>Easy tool-free handling and cleaning</li>
<li>Smaller chambers made of glass to avoid O<span>2</span> storage/release</li>
<li>Built-in baffles for even distribution of flow</li>
</ul>
<ul>
<li>For flushing and recirculating the water in the chamber pumps are needed. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>To connect the pumps with the respirometer tubing is needed.</li>
<li>Place the oxygen probe in one of our inline flow-through chambers (D025, D026, D027).</li>
<li>Replacement glass tubes are available, please contact us for details.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d007-static-respirometry-chamber-33mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D003 Static Respirometry Chamber (62mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d003-static-respirometry-chamber-62mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d003-static-respirometry-chamber-62mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 14:29:36 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often fish) (62mm ID) 
]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/d003-copy.png"><img class="aligncenter size-full wp-image-2507" title="d003 copy" src="/wp-content/uploads/2010/06/d003-copy.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most oftenly fish). The chambers have 2 ports located on each end to allow water flow in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber. <strong>The D003 Respirometry Chamber</strong> is 62 mm ID and of user-specified length.</p>
<p><strong>Features:</strong></p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<ul>
<li>Free choice of chamber length, and 8 different inner diameters</li>
<li>Chambers made for use in full strength sea water</li>
<li>Easy tool-free handling and cleaning</li>
<li>Smaller chambers made of glass to avoid O2 storage/release</li>
<li>Built-in baffles for even distribution of flow</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p><strong>Included:</strong></p>
<ul>
<li>Glass or acrylic chamber of user-specified length</li>
<li>Two end caps</li>
<li>Stainless wing nuts and washers</li>
<li>Four threaded plastic hose fittings</li>
<li>Extra rubber o-ring</li>
<li>Extra two wing nuts and washers</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d003-static-respirometry-chamber-62mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>D002 Static Respirometry Chamber (100mm ID)</title>
		<link>http://qubitsystems.com/aquatic/d002-static-respirometry-chamber-100mm-id/</link>
		<comments>http://qubitsystems.com/aquatic/d002-static-respirometry-chamber-100mm-id/#comments</comments>
		<pubDate>Tue, 08 Jun 2010 13:30:15 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Respirometry]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Respirometry]]></category>
		<category><![CDATA[Respirometry Chambers]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often, fish) (100mm ID)
]]></description>
			<content:encoded><![CDATA[<p><a href="/wp-content/uploads/2010/06/D002.png"><img class="aligncenter size-full wp-image-2504" title="D002" src="/wp-content/uploads/2010/06/D002.png" alt="" width="550" height="350" /></a>Qubit&#8217;s respirometry chambers are specifically designed for intermittent flow respirometry measurements on aquatic organisms (most often, fish). The chambers have 2 ports located on each end of the to allow water in and out. A dissolved oxygen probe is inserted into a separate chamber (D025, D026 or D027). Baffles at each end of the chamber provide laminar flow through the entire chamber. <strong>D002 Static Respirometry Chamber</strong> is 100mm ID and has user-specified length.</p>
<p><strong>Features:</strong></p>
<ul>
<li>Use the respirometers with your own oxygen and data acquisition equipment or with our systems for automatic respirometry.</li>
<li>Pumps are required for flushing and recirculating water in the chamber. We suggest pumps with a flow rate per minute five times the chamber volume (e.g. if chamber volume is 1 L, we recommend a 5 L/min pump).</li>
<li>Tubing is required to connect the pumps with the respirometer.</li>
<li>Replacement tubes are available, please contact us for details.</li>
</ul>
<ul>
<li>Free choice of chamber length, and 8 different inner diameters</li>
<li>Chambers made for use in full strength sea water</li>
<li>Easy tool-free handling and cleaning</li>
<li>Smaller chambers made of glass to avoid O2 storage/release</li>
<li>Built-in baffles for even distribution of flow</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<thead>
<tr>
<th>Product #</th>
<th>Chamber ID (mm)</th>
<th>Chamber Length (mm)</th>
<th>Fittings OD (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td>D007</td>
<td>33**</td>
<td>User-specified</td>
<td>3.2</td>
</tr>
<tr>
<td>D008</td>
<td>45**</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D003</td>
<td>62</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D009</td>
<td>72</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D011</td>
<td>80</td>
<td>User-specified</td>
<td>11</td>
</tr>
<tr>
<td>D002</td>
<td>100</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D010</td>
<td>140</td>
<td>User-specified</td>
<td>14</td>
</tr>
<tr>
<td>D012</td>
<td>190</td>
<td>User-specified</td>
<td>14</td>
</tr>
</tbody>
</table>
<p>**35 and 45mm chambers made from glass</p>
<p><strong>Included:</strong></p>
<ul>
<li>Glass or acrylic chamber of user-specified length</li>
<li>Two end caps</li>
<li>Stainless wing nuts and washers</li>
<li>Four threaded plastic hose fittings</li>
<li>Extra rubber o-ring</li>
<li>Extra two wing nuts and washers</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/aquatic/d002-static-respirometry-chamber-100mm-id/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

