<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Qubit Systems Inc. &#187; Environmental Sensing</title>
	<atom:link href="http://qubitsystems.com/category/product_list/environemental-sensing/feed/" rel="self" type="application/rss+xml" />
	<link>http://qubitsystems.com</link>
	<description>Instrumentation for the Biological Sciences</description>
	<lastBuildDate>Tue, 08 May 2012 18:38:43 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1.1</generator>
		<item>
		<title>S141 Light Sensor</title>
		<link>http://qubitsystems.com/environmental/s141-light-sensor/</link>
		<comments>http://qubitsystems.com/environmental/s141-light-sensor/#comments</comments>
		<pubDate>Fri, 02 Jul 2010 17:25:30 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Environmental Sensors]]></category>
		<category><![CDATA[Light]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Provides irradiance data in units of µmol quanta/m2/s from halogen light source.]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/07/S141-Light-Sensor.jpg"><img class="alignnone size-full wp-image-3079" title="S141 Light Sensor" src="http://qubitsystems.com/wp-content/uploads/2010/07/S141-Light-Sensor.jpg" alt="" width="435" height="224" /></a></p>
<p>The <strong>S141 Light Sensor</strong> has been developed for use with the <a href="http://qubitsystems.com/algae-and-bacteria/light-sources-algaebacteria/a111-halogen-light-source/" target="_blank"><span style="text-decoration: underline;">A111</span></a> Halogen Light Source and <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank"><span style="text-decoration: underline;">C901</span></a> Logger Pro software to provide irradiance data in units of µmol quanta/m2/s. Customized setup and calibration files are available to users of Logger Pro software. The sensor can be calibrated by the user for stand-alone operation or for relative measurements of light intensity.  The maximum photosensitivity of the sensor is in the 500-600nm range (most appropriate for halogen light source).</p>
<p>The Light Sensor may be mounted directly under Qubit Systems&#8217; <a href="http://qubitsystems.com/plant-and-soil/g112-flow-through-leaf-chamber/" target="_blank"><span style="text-decoration: underline;">G112</span></a> Flow-Through Leaf Chamber for use in photosynthesis measurements with the halogen light source.</p>
<p>The S141 Light Sensor is included in <a href="http://qubitsystems.com/plant-and-soil/ph1lp-photosynthesis-package/" target="_blank">PH1LP Photosynthesis Package</a></p>
<p><strong>Specifications:</strong></p>
<ul>
<li>0-4 V analog output to data interface</li>
<li>Small surface area (2.4 x 2.8 mm)</li>
<li>Selectable ranges (0-100, 0-300, 0-1150 µmol quanta/m2/s) with corrections for use under leaves or in direct halogen light.</li>
<li>size (h/w/l) cm:  3.0/5.4/8.3</li>
<li>weight (g): 110</li>
<li>materials: plastic (black)</li>
<li>warranty: 1 years</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/environmental/s141-light-sensor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S132 Temperature Probe</title>
		<link>http://qubitsystems.com/environmental/s132-temperature-probe/</link>
		<comments>http://qubitsystems.com/environmental/s132-temperature-probe/#comments</comments>
		<pubDate>Fri, 02 Jul 2010 17:10:39 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Environmental Sensors]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Can be used for temperature measurements in organic liquids, salt solutions, acids, and bases.]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/07/S132-temperature-probe1.jpg"><img class="alignnone size-medium wp-image-3652" title="S132 temperature probe" src="http://qubitsystems.com/wp-content/uploads/2010/07/S132-temperature-probe1-300x144.jpg" alt="" width="300" height="144" /></a></p>
<p>the <strong>S132 Stainless Steel Temperature Probe</strong> is a rugged and durable probe with a sealed stainless steel shaft and tip that can be used in organic liquids, salt solutions, acids, and bases.</p>
<p>The S132 temperature sensor is included in the <a href="http://qubitsystems.com/algae-and-bacteria/gas-analyzers-algae-bacteria/nf1lp-nitrogen-fixation-package/" target="_blank"><span style="text-decoration: underline;">NF1LP Nitrogen Fixation Package</span></a>, <span style="text-decoration: underline;"><a href="http://qubitsystems.com/algae-and-bacteria/soil-biology-algae-bacteria/sr1lp-soil-respiration-package/" target="_blank">SR1LP Soil Respiration</a></span> and <span style="text-decoration: underline;"><a href="http://qubitsystems.com/animal-and-insect/rp2lp-high-range-respiration-package/" target="_blank">RP2LP</a></span> and <a href="http://qubitsystems.com/animal-and-insect/rp1lp-low-range-respiration-package/" target="_blank"><span style="text-decoration: underline;">RP1LP</span> Respiration Packages</a>. It is also available for sale individually and can be modified to work with any data acquisition hardware and software.</p>
<p><strong>Specifications:</strong></p>
<ul>
<li><strong>Temperature Range</strong>: -40 to 135oC</li>
<li><strong>12-bit resolution </strong>(when used with LabPro Interface):0.17<sup>o</sup>C when used in the range: -40 to 0<sup>o</sup>C, 0.03<sup>o</sup>C when used in the range: 0 to 40<sup>o</sup>C, 0.1<sup>o</sup>C when used in the range: 40 to 100<sup>o</sup>C, 0.25<sup>o</sup>C when used in the range: 100 to 135<sup>o</sup>C</li>
<li><strong>Accuracy:</strong> +/-0.2<sup>o</sup>C at 0<sup>o</sup>C, +/-0.5<sup>o</sup>C at 100<sup>o</sup>C</li>
<li><strong>Response time (t90)</strong>:  10 sec (in water, with stirring),  90 sec (in moving air),  400 sec (in still air)</li>
<li><strong>Dimensions: </strong>Length (handle + body) = 15.5 cm, Stainless steel body = length &#8211; 10.5 cm, diameter &#8211; 4.0 mm, Probe handle = length &#8211; 5.0 cm, diameter &#8211; 1.25 cm</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/environmental/s132-temperature-probe/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S125 Conductivity Sensor</title>
		<link>http://qubitsystems.com/environmental/s125-conductivity-sensor/</link>
		<comments>http://qubitsystems.com/environmental/s125-conductivity-sensor/#comments</comments>
		<pubDate>Fri, 02 Jul 2010 16:59:53 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Environmental Sensors]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Used for environmental testing of salinity, total dissolved solids (TDS), or conductivity in water samples]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/07/S125-Conductivity-Sensor.jpg"><img class="alignnone size-medium wp-image-3277" title="S125 Conductivity Sensor" src="http://qubitsystems.com/wp-content/uploads/2010/07/S125-Conductivity-Sensor-300x145.jpg" alt="" width="300" height="145" /></a></p>
<p><span>The <strong>S125 Conductivity Sensor</strong> is used for environmental testing of salinity, total dissolved solids (TDS), or conductivity in water samples.</span></p>
<p><span>The <strong>S125 Conductivity Sensor</strong> can be used in teaching to demonstrate diffusion of ions through membranes or to monitor changes in ion levels in aquatic systems. In Chemistry education  it can be used  to investigate the difference between ionic and molecular compounds, strong and weak acids, or ionic compounds that yield different ratios of ions. The Conductivity Probe can monitor concentration or conductivity at three different sensitivity settings.</span></p>
<p><span>Readings can be taken in units of conductivity (µS/cm) or concentration (mg/L TDS as NaCl) At three different sensitivity settings:</span></p>
<p><span>0-100 mg/L TDS or 0-200 µS/cm<br />
0-1000 mg/L TDS or 0-2000 µS/cm<br />
0-10000 mg/L TDS or 0-20,000 µS/cm</span></p>
<p><span>Conductivity is directly proportional to concentration over the entire range.</span></p>
<p><span>The probe has a fast response time, reaching 98% of full value in less than 5 seconds. We recommend using it with <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c410-labpro-data-acquisition-interface/" target="_blank"><span style="text-decoration: underline;">C410 LabPro acquisition Interface</span></a> or <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c420-go-link-usb-data-acquisition-interface/" target="_blank"><span style="text-decoration: underline;">C420 Go-Link USB data acquisition interface</span></a> and <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank"><span style="text-decoration: underline;">C901 LoggerPro data acquisition software</span></a>.  You can load pre-saved calibrations.  Alternatively, you can do a quick two-point calibration: the probe is left out of solution for one calibration point (0 µS/cm) and is placed in a known standard (1000 µS/cm solution is provided) for a second calibration point. More precise calibration in two different standards is also possible using our <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank"><span style="text-decoration: underline;">C901 LoggerPro software</span></a>.</span></p>
<p><span>The <strong>S125 Conductivity Sensor</strong> uses alternating current at its electrodes; this prevents polarization and electrolysis, so that solutions being tested are not fouled. Corrosion of metal electrodes is not a problem with this epoxy-body graphite electrode. It has built-in temperature compensation, which allows performance of calibrations in the lab, and measurements outdoors without temperature changes affecting conductivity readings.</span></p>
<p><span>The <strong>S125 Conductivity Sensor</strong> comes with a Sodium Chloride Calibration Standard (equivalent to 1000 uS/cm, 491 mg/L as NaCI, or 500 mg/L TDS) and the Conductivity Sensor Manual.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/environmental/s125-conductivity-sensor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S181 Absolute Pressure Sensor</title>
		<link>http://qubitsystems.com/environmental/s181-absolute-pressure-sensor/</link>
		<comments>http://qubitsystems.com/environmental/s181-absolute-pressure-sensor/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 15:02:05 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Atmospheric Gas Control]]></category>
		<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Environmental Sensors]]></category>
		<category><![CDATA[Gas Mixing & Flow Control]]></category>
		<category><![CDATA[Pressure Sensors & Regulators]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Used as a stand alone sensor to measure atmospheric pressure]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S181-Absolute-Pressure-sensor.jpg"><img class="alignnone size-medium wp-image-3600" title="S181 Absolute Pressure sensor" src="http://qubitsystems.com/wp-content/uploads/2010/06/S181-Absolute-Pressure-sensor-300x171.jpg" alt="" width="300" height="171" /></a></p>
<p>The <strong>S181 Absolute Pressure Sensor</strong> is typically used as a stand alone sensor to measure atmospheric pressure. To collect and display the data consider our<a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c410-labpro-data-acquisition-interface/" target="_blank"><span style="text-decoration: underline;"> C410 LabPro data acquisition</span> </a>interface and <span style="text-decoration: underline;"><a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank">C901 LoggerPro software</a></span></p>
<p><strong>Specifications:</strong></p>
<ul>
<li>State-of-the-art monolithic silicon pressure sensor</li>
<li>Response Time: 1 ms</li>
<li>Pressure Range: 15 &#8211; 115 kPa</li>
<li>Voltage Output: 0 &#8211; 2 V</li>
<li>Temperature Compensated</li>
<li>Analog output may be recorded by a chart recorder or Analong-to-Digital Interface (<span style="text-decoration: underline;"><a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c410-labpro-data-acquisition-interface/" target="_blank">C410 LabPro Interface</a></span>)</li>
<li>warranty: 1 years</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/environmental/s181-absolute-pressure-sensor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S172 Dissolved O2 Cuvette Thermistor</title>
		<link>http://qubitsystems.com/product_list/accessories/s172-dissolved-o2-cuvette-thermistor/</link>
		<comments>http://qubitsystems.com/product_list/accessories/s172-dissolved-o2-cuvette-thermistor/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 14:00:34 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[temperature]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Incorporated into the plunger of the dissolved O2 cuvette so that it measures the temperature of the sample directly.]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S172-dissolved-O2-cuvette-sensor.jpg"><img class="alignnone size-full wp-image-3084" title="S172 dissolved O2 cuvette sensor" src="http://qubitsystems.com/wp-content/uploads/2010/06/S172-dissolved-O2-cuvette-sensor.jpg" alt="" width="450" height="213" /></a></p>
<p>The <strong>S172Dissolved O2 Cuvette Thermistor</strong> is incorporated into the plunger of the cuvette so that it measures the temperature of the sample directly. This allows corrections to be made for measurements of dissolved oxygen when the oxygen electrode is calibrated at one temperature and used at a different temperature. It also allows accurate investigations of the temperature dependence of physiological and biochemical processes.</p>
<p>The tip of the thermistor is very fine and encased in glass. It protrudes slightly from the lower surface of the plunger to make contact with liquid in the sample chamber.</p>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/product_list/accessories/s172-dissolved-o2-cuvette-thermistor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S171 Leaf Chamber Thermistor</title>
		<link>http://qubitsystems.com/product_list/accessories/s171-leaf-chamber-thermistor/</link>
		<comments>http://qubitsystems.com/product_list/accessories/s171-leaf-chamber-thermistor/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 13:50:58 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[A glass coated thermocouple sensor that fits into the base of flow-through leaf chamber for measurements of leaf surface temperature.  It is essential for studying leaf CO2 and water vapor conductance.]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S171-Leaf-Chamber-Thermistor.jpg"><img class="alignnone size-medium wp-image-3289" title="S171 Leaf Chamber Thermistor" src="http://qubitsystems.com/wp-content/uploads/2010/06/S171-Leaf-Chamber-Thermistor-300x140.jpg" alt="" width="300" height="140" /></a></p>
<p>The <strong>S171 Leaf Chamber Thermistor</strong> is accurate and rapid in measuring of leaf surface temperature.   It is essential for studying leaf CO2 and water vapor conductance.</p>
<p>The <strong>S171 Leaf Chamber Thermistor&#8217;s</strong> sensor head is a glass coated thermocouple and only 0.75 mm in diameter. The sensor housing screws into the base of the <a href="http://qubitsystems.com/plant-and-soil/g112-flow-through-leaf-chamber/" target="_blank"><span style="text-decoration: underline;">G112 Flow-Through Leaf Chamber</span></a> and the sensor position can be easily adjusted to touch the surface of the leaf.</p>
<p>The S171 Leaf Chamber Thermistor is an optional addition to <span style="text-decoration: underline;"><a href="http://qubitsystems.com/plant-and-soil/co650-fcm-advanced-co2-analysis-package/" target="_blank">Q-Box CO650 </a></span>Plant CO2 Analysis Packages. It comes fully calibrated and plugs directly into the <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c410-labpro-data-acquisition-interface/" target="_blank"><span style="text-decoration: underline;">C410 LabPro Interface</span></a> and displays values of leaf temperature on a computer screen using <a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank"><span style="text-decoration: underline;">C901 Logger Pro Software</span></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/product_list/accessories/s171-leaf-chamber-thermistor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S165 pH Sensor</title>
		<link>http://qubitsystems.com/algae-and-bacteria/s165-ph-sensor/</link>
		<comments>http://qubitsystems.com/algae-and-bacteria/s165-ph-sensor/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 13:29:16 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Algae & Bacteria]]></category>
		<category><![CDATA[Aquatic]]></category>
		<category><![CDATA[Aquatic Control]]></category>
		<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Environmental Sensors]]></category>
		<category><![CDATA[Product List]]></category>
		<category><![CDATA[Water Quality]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Can be substituted for any traditional pH meter and used with automated data collection, graphing and data analysis.]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S165-pH-sensor.jpg"><img class="alignnone size-medium wp-image-3598" title="S165 pH sensor" src="http://qubitsystems.com/wp-content/uploads/2010/06/S165-pH-sensor-300x137.jpg" alt="" width="300" height="137" /></a></p>
<p>Qubit&#8217;s <strong>S165 pH Sensor</strong> can be substituted for any traditional pH meter. The advantages are trifold: automated data collection, graphing and data analysis using the<a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c410-labpro-data-acquisition-interface/" target="_blank"><span style="text-decoration: underline;"> C410 LabPro Interface</span> </a>and <span style="text-decoration: underline;"><a href="http://qubitsystems.com/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank">C901 Logger Pro Software</a></span>. For field work, it can be used with a Palm hand-held computer and C915 Palm/Data Pro software.</p>
<ul>
<li>materials: Sealed, gel-filled, epoxy body, Ag/AgCI</li>
<li>Response time: 90% of final reading in 1 second</li>
<li>Temperature range: 5 to 80<sup>o</sup>C</li>
<li>12 mm Outer Diameter</li>
<li>pH range: pH 0 &#8211; 14</li>
<li>12 bit resolution (with LabPro Interface) 0.005 pH units</li>
<li>Isopotential pH:  pH 7</li>
<li>Output: 59.2 mV/pH at 25<sup>o</sup>C</li>
<li>warranty : 2 years</li>
</ul>
<p>The pH sensor is factory-calibrated. If re-calibration is required, it is a simple two point procedure using buffer solutions. Qubit can supply a buffer kit including 4 tablets each of buffer pH 4, 7, and 10. Each tablet is added to 100 mL of distilled water to prepare respective pH buffer solutions.</p>
<p><strong>Applications include: </strong></p>
<ul>
<li>Acid-base titrations</li>
<li>Investigations of acid rain and buffering</li>
<li>Investigations of water quality in streams and lakes</li>
<li>Monitoring pH change during chemical reactions</li>
<li>Monitoring pH changes in an aquarium as a result of photosynthesis</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://qubitsystems.com/algae-and-bacteria/s165-ph-sensor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>S161 Air Temperature &amp; Humidity Sensor</title>
		<link>http://qubitsystems.com/environmental/s161-air-temperature-humidity-sensor/</link>
		<comments>http://qubitsystems.com/environmental/s161-air-temperature-humidity-sensor/#comments</comments>
		<pubDate>Wed, 30 Jun 2010 13:07:45 +0000</pubDate>
		<dc:creator>MK</dc:creator>
				<category><![CDATA[Environmental]]></category>
		<category><![CDATA[Environmental Sensing]]></category>
		<category><![CDATA[Environmental Sensors]]></category>
		<category><![CDATA[Photos. Respir. & transpir.]]></category>
		<category><![CDATA[Plant & Soil]]></category>
		<category><![CDATA[Product List]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Simultaneous measurements of relative humidity and air temperature]]></description>
			<content:encoded><![CDATA[<p><a href="http://qubitsystems.com/wp-content/uploads/2010/06/S161-Air-temp.-and-humidity-sensor.jpg"><img class="alignnone size-medium wp-image-3295" title="S161 Air temp. and humidity sensor" src="http://qubitsystems.com/wp-content/uploads/2010/06/S161-Air-temp.-and-humidity-sensor-300x156.jpg" alt="" width="300" height="156" /></a></p>
<p>Qubit Systems&#8217; combined <strong>S161 Humidity and Temperature Sensor</strong> allows simultaneous measurements of relative humidity and air temperature in a flow through gas. Water vapor concentration can then be calculated in absolute units. No calibration is needed if used with  <a href="/plant-and-soil/data-acquisition-plantsoil/c901-loggerpro-data-acquisition-software/" target="_blank">C901 Logger Pro software</a> and the associated calibration files (factory calibrated).  We recommend the use of <span style="text-decoration: underline;"><a href="http://qubitsystems.com/product_list/data-aqcuisition-software/c410-labpro-data-acquisition-interface/" target="_blank">C410 LabPro </a></span>data acquisition interface with S161 for logging the temperature and relative humidity of a gas.</p>
<p>The <strong>S161 Humidity and Temperature sensor</strong> is only 5 x 8 x 3 (cm) and has a temperature range of -50 to 100°C. The relative humidity  range is from 0 to 100%.</p>
<p>The S161 Humidity and Temperature Sensor is ideal for transpiration measurements in an open-flow gas exchange system. It comes with our <a href="/plant-and-soil/co650-advanced-co2-analysis-package/" target="_blank"><span style="text-decoration: underline;">CO650 Advanced CO2 Analysis Packages</span></a> and is optional in the <a href="/plant-and-soil/co750-field-co2-analysis-package/" target="_blank"><span style="text-decoration: underline;">CO750 Field Package</span></a>.</p>
<p>It may also be used to study water loss from animals or to observe temperature and humidity levels in environmental chambers.</p>
<p><strong>Specifications:</strong></p>
<ul>
<li>power supply: 9V, 0.56A</li>
<li>size (h/w/l): 3.0cm/5.4cm/8.3cm</li>
<li>weight : 200 g</li>
<li>materials plastic (black)</li>
<li>warranty: 1 years</li>
</ul>